{"id":28791,"date":"2026-07-06T19:42:27","date_gmt":"2026-07-06T17:42:27","guid":{"rendered":"https:\/\/www.heliotis.com\/mises-a-jour-du-micrologiciel-1-11-1-12-ameliorations-de-la-plateforme-gen4-pour-heliinspect-et-helicam\/"},"modified":"2026-07-07T08:27:07","modified_gmt":"2026-07-07T06:27:07","slug":"mises-a-jour-du-micrologiciel-1-11-1-12-ameliorations-de-la-plateforme-gen4-pour-heliinspect-et-helicam","status":"publish","type":"post","link":"https:\/\/www.heliotis.com\/fr\/mises-a-jour-du-micrologiciel-1-11-1-12-ameliorations-de-la-plateforme-gen4-pour-heliinspect-et-helicam\/","title":{"rendered":"Mises \u00e0 jour du micrologiciel 1.11\/1.12 &#8211; Am\u00e9liorations de la plateforme Gen4 pour heliInspect\u2122 et heliCam\u2122"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Avec les versions 1.11 et 1.12 du micrologiciel, Heliotis continue de d\u00e9velopper de mani\u00e8re coh\u00e9rente la plateforme Gen4 pour heliInspect et heliCam. Outre de nombreuses am\u00e9liorations de d\u00e9tail, les utilisateurs b\u00e9n\u00e9ficient notamment d\u2019une pr\u00e9cision de mesure accrue des interf\u00e9rom\u00e8tres \u00e0 lumi\u00e8re blanche heliInspect, d\u2019une plage de mesure verticale plus \u00e9tendue, de nouvelles possibilit\u00e9s d\u2019int\u00e9gration ainsi que de fonctions suppl\u00e9mentaires pour les cam\u00e9ras Lock-in heliCam. <\/p>\n\n<p class=\"wp-block-paragraph\">Comme \u00e0 l\u2019accoutum\u00e9e, toutes les am\u00e9liorations sont \u00e0 la disposition des clients existants via une mise \u00e0 jour du micrologiciel \u2013 un remplacement du mat\u00e9riel n\u2019est pas n\u00e9cessaire.<\/p>\n\n<h3 class=\"wp-block-heading\">Pr\u00e9cision de mesure accrue gr\u00e2ce \u00e0 une acquisition de donn\u00e9es et une reconstruction de surface optimis\u00e9es<\/h3>\n\n<p class=\"wp-block-paragraph\">La pr\u00e9cision de mesure d\u2019un interf\u00e9rom\u00e8tre \u00e0 lumi\u00e8re blanche n\u2019est pas d\u00e9termin\u00e9e uniquement par l\u2019optique et la m\u00e9canique. Il est tout aussi crucial de savoir comment les signaux d\u2019interf\u00e9rence sont acquis pendant le balayage et analys\u00e9s par la suite. Avec le micrologiciel 1.11, deux am\u00e9liorations fondamentales ont donc \u00e9t\u00e9 introduites pour agir pr\u00e9cis\u00e9ment sur ces points.  <\/p>\n\n<h4 class=\"wp-block-heading\">R\u00e9f\u00e9rencement bas\u00e9 sur l\u2019encodeur<\/h4>\n\n<p class=\"wp-block-paragraph\">Dans les versions pr\u00e9c\u00e9dentes du micrologiciel, les trames de mesure enregistr\u00e9es lors d\u2019un balayage \u00e9taient d\u00e9j\u00e0 li\u00e9es \u00e0 la position actuelle de l\u2019encodeur de l\u2019axe de balayage. Cela permettait de compenser largement les \u00e9carts par rapport \u00e0 une vitesse de balayage constante d\u00e8s la reconstruction. <\/p>\n\n<p class=\"wp-block-paragraph\">Avec le nouveau mode \u00ab Encoder-Based Reference \u00bb, l\u2019acquisition des donn\u00e9es franchit une \u00e9tape suppl\u00e9mentaire. Les trames de mesure ne sont plus enregistr\u00e9es \u00e0 une fr\u00e9quence d\u2019images fixe pour \u00eatre ensuite affect\u00e9es \u00e0 une position d\u2019encodeur. Au lieu de cela, l\u2019axe de balayage d\u00e9clenche chaque prise de vue directement \u00e0 une position d\u2019encodeur d\u00e9finie. Ainsi, les trames de mesure sont g\u00e9n\u00e9r\u00e9es d\u00e8s l\u2019acquisition \u00e0 des intervalles \u00e9quidistants de \u03bb\/8.   <\/p>\n\n<p class=\"wp-block-paragraph\">Outre une affectation de position encore am\u00e9lior\u00e9e, le traitement du signal dans le capteur d\u2019image heliSens en profite \u00e9galement, car la d\u00e9modulation Lock-in s\u2019effectue dans des conditions d\u2019\u00e9chantillonnage id\u00e9ales. Associ\u00e9 au nouveau mode \u00ab CenterOfMassPhaseFusion \u00bb, l\u2019\u00ab Encoder-Based Reference Mode \u00bb constitue la base de l\u2019am\u00e9lioration significative de la r\u00e9p\u00e9tabilit\u00e9 pr\u00e9sent\u00e9e dans la section suivante. <\/p>\n\n<h4 class=\"wp-block-heading\">CenterOfMassPhaseFusion comme mode d\u2019extraction int\u00e9gr\u00e9<\/h4>\n\n<p class=\"wp-block-paragraph\">Avec le micrologiciel 1.11, la reconstruction de surface a \u00e9t\u00e9 enrichie du nouveau mode d\u2019extraction CenterOfMassPhaseFusion. L\u2019algorithme combine l\u2019information de position robuste et univoque de l\u2019enveloppe de coh\u00e9rence avec l\u2019information de phase nettement plus pr\u00e9cise. Il r\u00e9unit ainsi les avantages des deux m\u00e9thodes d\u2019\u00e9valuation : une large plage de mesure univoque combin\u00e9e \u00e0 une pr\u00e9cision de mesure maximale.  <\/p>\n\n<p class=\"wp-block-paragraph\">Alors que cet algorithme devait jusqu\u2019\u00e0 pr\u00e9sent \u00eatre appel\u00e9 comme \u00e9tape de traitement s\u00e9par\u00e9e \u00e0 partir de la biblioth\u00e8que heliAlgo, il est d\u00e9sormais directement int\u00e9gr\u00e9 dans l\u2019\u00e9valuation standard de la plateforme Gen4 et disponible en tant que mode d\u2019extraction natif via l\u2019API. Les applications b\u00e9n\u00e9ficient ainsi de la reconstruction am\u00e9lior\u00e9e sans effort d\u2019impl\u00e9mentation suppl\u00e9mentaire \u2013 qu\u2019elles acc\u00e8dent \u00e0 la cam\u00e9ra via GenICam, HALCON, MATLAB, Python ou d\u2019autres environnements logiciels. <\/p>\n\n<p class=\"wp-block-paragraph\">Associ\u00e9 au r\u00e9f\u00e9rencement bas\u00e9 sur l\u2019encodeur, le CenterOfMassPhaseFusion permet l\u2019am\u00e9lioration significative de la r\u00e9p\u00e9tabilit\u00e9 pr\u00e9sent\u00e9e dans la section suivante.<\/p>\n\n<h4 class=\"wp-block-heading\">R\u00e9p\u00e9tabilit\u00e9 am\u00e9lior\u00e9e<\/h4>\n\n<p class=\"wp-block-paragraph\">La combinaison du r\u00e9f\u00e9rencement bas\u00e9 sur l\u2019encodeur et du nouveau mode de reconstruction CenterOfMassPhaseFusion am\u00e9liore consid\u00e9rablement la r\u00e9p\u00e9tabilit\u00e9, en particulier pour les mesures de hauteur de marche de haute pr\u00e9cision. Alors que les am\u00e9liorations pr\u00e9c\u00e9dentes contribuent d\u00e9j\u00e0 individuellement \u00e0 une meilleure qualit\u00e9 de mesure, leur combinaison permet d\u2019obtenir les meilleurs r\u00e9sultats. <\/p>\n\n<p class=\"wp-block-paragraph\">La mesure comparative suivante montre l\u2019\u00e9cart-type de mesures de hauteur de marche r\u00e9p\u00e9t\u00e9es pour diff\u00e9rents proc\u00e9d\u00e9s d\u2019acquisition de donn\u00e9es et de reconstruction. Selon la t\u00e2che de mesure et la configuration, la r\u00e9p\u00e9tabilit\u00e9 peut \u00eatre encore nettement augment\u00e9e par rapport \u00e0 l\u2019\u00e9valuation standard actuelle. <\/p>\n\n<p class=\"wp-block-paragraph\">Les valeurs indiqu\u00e9es se rapportent \u00e0 la r\u00e9p\u00e9tabilit\u00e9 de pixels individuels du capteur d\u2019image par rapport \u00e0 un plan de r\u00e9f\u00e9rence. Contrairement \u00e0 de nombreuses fiches techniques publi\u00e9es, aucune moyenne n\u2019est effectu\u00e9e sur de grandes surfaces ou sur plusieurs centaines de pixels, ce qui signifie que les r\u00e9sultats de mesure refl\u00e8tent de mani\u00e8re conservatrice les performances r\u00e9elles du syst\u00e8me. Les mesures ont \u00e9t\u00e9 effectu\u00e9es sur un heliInspect H8 Ultra sans amortissement actif des vibrations.  <\/p>\n\n<figure class=\"wp-block-table\"><style>.heliotis-table {\n  width: 100%;\n  border-collapse: collapse;\n  font-family: inherit;\n  font-size: 14px;\n  color: #101828;\n  margin: 24px 0;\n}\n\n.heliotis-table th,\n.heliotis-table td {\n  border: 1px solid #d0d5dd;\n  padding: 8px 9px;\n  text-align: center;\n  vertical-align: middle;\n}\n\n.heliotis-table thead tr.level1 th {\n  background: #424c54;\n  color: #ffffff;\n  font-weight: 600;\n  font-size: 15px;\n}\n\n.heliotis-table thead tr.level2 th {\n  background: #f6a800;\n  color: #101828;\n  font-weight: 600;\n  font-size: 13px;\n  line-height: 1.15;\n}\n\n.heliotis-table thead tr.level3 th {\n  background: #f2f4f7;\n  color: #101828;\n  font-weight: 600;\n  font-size: 12px;\n  line-height: 1.15;\n}\n\n.heliotis-table tbody tr:nth-child(even) {\n  background: #f9fafb;\n}\n\n.heliotis-table tbody tr:hover {\n  background: #fff8ea;\n}\n\n.heliotis-table .left {\n  text-align: left;\n  font-weight: 600;\n}\n\n.heliotis-table .divider-left {\n  border-left: 3px solid #f6a800;\n}\n\n.heliotis-table .best-head {\n  background: #f6a800 !important;\n}\n\n.heliotis-table .best {\n  background: #fff6de;\n}\n\n.heliotis-table .best-sigma {\n  background: #fff6de;\n  color: #c57a00;\n  font-weight: 700;\n}\n<\/style><table class=\"heliotis-table\"><thead><tr class=\"level1\"><th rowspan=\"3\">Step Height<br\/>[\u00b5m]<\/th><th rowspan=\"3\">Target<br\/>\u00b1 nm<\/th><th colspan=\"4\">Time-Based Referenz<\/th><th colspan=\"4\" class=\"divider-left\">Encoder-Based Referenz<\/th><\/tr><tr class=\"level2\"><th colspan=\"2\">Improved<br\/>Center of Mass<\/th><th colspan=\"2\">Center of Mass<br\/>Phase Fusion<\/th><th colspan=\"2\" class=\"divider-left\">Improved<br\/>Center of Mass<\/th><th colspan=\"2\" class=\"best-head\">Center of Mass<br\/>Phase Fusion<\/th><\/tr><tr class=\"level3\"><th>\u03c3<br\/>[nm]<\/th><th>Hight<br\/>[\u00b5m]<\/th><th>\u03c3<br\/>[nm]<\/th><th>Hight<br\/>[\u00b5m]<\/th><th class=\"divider-left\">\u03c3<br\/>[nm]<\/th><th>Height<br\/>[\u00b5m]<\/th><th class=\"best-head\">\u03c3<br\/>[nm]<\/th><th class=\"best-head\">H\u00f6he<br\/>[\u00b5m]<\/th><\/tr><\/thead><tbody><tr><td class=\"left\">1.002<\/td><td>24<\/td><td>20<\/td><td>1.002<\/td><td>5<\/td><td>1.003<\/td><td class=\"divider-left\">16<\/td><td>1.001<\/td><td class=\"best-sigma\">1<\/td><td class=\"best\">1.002<\/td><\/tr><tr><td class=\"left\">5.009<\/td><td>22<\/td><td>20<\/td><td>4.991<\/td><td>7<\/td><td>4.996<\/td><td class=\"divider-left\">16<\/td><td>4.998<\/td><td class=\"best-sigma\">2<\/td><td class=\"best\">4.999<\/td><\/tr><tr><td class=\"left\">20.000<\/td><td>26<\/td><td>20<\/td><td>19.984<\/td><td>7<\/td><td>19.994<\/td><td class=\"divider-left\">16<\/td><td>20.000<\/td><td class=\"best-sigma\">2.5<\/td><td class=\"best\">19.997<\/td><\/tr><tr><td class=\"left\">900.54<\/td><td>40<\/td><td>20<\/td><td>900.55<\/td><td>7<\/td><td>900.58<\/td><td class=\"divider-left\">16<\/td><td>900.57<\/td><td class=\"best-sigma\">3.3<\/td><td class=\"best\">900.56<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">Comparison of Repeatability for Different Data Acquisition and Reconstruction Methods. The values indicate the standard deviation \u03c3 obtained from repeated single-pixel step-height measurements relative to a reference plane. Lower values correspond to higher repeatability. Measurements were performed using a heliInspect H8 Ultra without active vibration isolation.\n<\/figcaption><\/figure>\n\n<div style=\"height:51px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Plage de mesure verticale plus \u00e9tendue gr\u00e2ce \u00e0 une utilisation plus efficace de la m\u00e9moire<\/h3>\n\n<p class=\"wp-block-paragraph\">Les syst\u00e8mes heliInspect n\u2019utilisent pas un capteur d\u2019image 2D conventionnel, mais le capteur d\u2019image Lock-in heliSens d\u00e9velopp\u00e9 par Heliotis. La d\u00e9modulation Lock-in s\u2019effectue directement dans le pixel. Par cons\u00e9quent, il n\u2019est pas n\u00e9cessaire de transmettre et d\u2019analyser l\u2019int\u00e9gralit\u00e9 des images brutes. Au lieu de cela, des donn\u00e9es de mesure d\u00e9modul\u00e9es sont g\u00e9n\u00e9r\u00e9es d\u00e8s le capteur, ce qui permet d\u2019effectuer des mesures en lumi\u00e8re blanche typiquement jusqu\u2019\u00e0 100 fois plus rapidement qu\u2019avec des capteurs d\u2019image conventionnels.   <\/p>\n\n<p class=\"wp-block-paragraph\">Chaque pixel int\u00e8gre le signal d\u2019interf\u00e9rence sur plusieurs cycles de modulation et m\u00e9morise les deux composantes du signal d\u00e9modul\u00e9 \u2013 la composante en phase (I) et la composante en quadrature (Q). Ces deux valeurs forment ensemble une trame de mesure. Lors d\u2019un balayage vertical, une pile compl\u00e8te de trames de mesure est ainsi cr\u00e9\u00e9e, contenant l\u2019information compl\u00e8te de l\u2019interf\u00e9rogramme enregistr\u00e9.  <\/p>\n\n<p class=\"wp-block-paragraph\">Pour la reconstruction de la surface, cette pile de trames de mesure doit \u00eatre enti\u00e8rement mise en m\u00e9moire tampon sur la cam\u00e9ra. Ce n\u2019est qu\u2019une fois le balayage termin\u00e9 que la cam\u00e9ra d\u00e9termine, \u00e0 partir des trames de mesure pour chaque pixel, la position du maximum d\u2019interf\u00e9rence et calcule ainsi la hauteur de la surface. La capacit\u00e9 de m\u00e9moire disponible d\u00e9termine donc directement le nombre maximal de trames de mesure et, par cons\u00e9quent, la plage de mesure verticale du syst\u00e8me.  <\/p>\n\n<p class=\"wp-block-paragraph\">Avec le micrologiciel 1.12, la gestion de la m\u00e9moire de la plateforme Gen4 a \u00e9t\u00e9 fondamentalement remani\u00e9e. Gr\u00e2ce \u00e0 une utilisation plus efficace de la m\u00e9moire disponible, la cam\u00e9ra peut d\u00e9sormais \u2013 selon le type de capteur \u2013 traiter jusqu\u2019\u00e0 trois fois plus de trames de mesure par acquisition. La plage de mesure verticale maximale utilisable augmente en cons\u00e9quence, sans qu\u2019aucune modification du mat\u00e9riel ne soit n\u00e9cessaire.  <\/p>\n\n<p class=\"wp-block-paragraph\">Selon l\u2019objectif, il est ainsi possible de capturer des <strong>plages de hauteur de plus d\u2019un centim\u00e8tre en un seul balayage continu<\/strong>. Pour des objets de mesure encore plus grands, la fonction \u00ab Segmented-Volume \u00bb est en outre disponible, laquelle fusionne automatiquement plusieurs sous-volumes verticaux en un jeu de donn\u00e9es 3D commun. <\/p>\n\n<figure class=\"wp-block-table\">\n\n<style>\n.heliotis-frame-table {\n  width: 100%;\n  border-collapse: collapse;\n  font-family: inherit;\n  font-size: 14px;\n  color: #101828;\n  margin: 24px 0;\n}\n\n.heliotis-frame-table th,\n.heliotis-frame-table td {\n  border: 1px solid #d0d5dd;\n  padding: 10px 12px;\n  vertical-align: middle;\n}\n\n.heliotis-frame-table thead th {\n  background: #424c54;\n  color: #ffffff;\n  font-weight: 600;\n}\n\n.heliotis-frame-table tbody tr:nth-child(even) {\n  background: #f9fafb;\n}\n\n.heliotis-frame-table tbody tr:hover {\n  background: #fff8ea;\n}\n\n.heliotis-frame-table th:first-child,\n.heliotis-frame-table td:first-child {\n  text-align: left;\n}\n\n.heliotis-frame-table th:nth-child(2),\n.heliotis-frame-table td:nth-child(2),\n.heliotis-frame-table th:nth-child(3),\n.heliotis-frame-table td:nth-child(3) {\n  text-align: right;\n}\n\n.heliotis-frame-table .highlight {\n  background: #fff6de;\n  color: #c57a00;\n  font-weight: 700;\n}\n<\/style>\n\n<table class=\"heliotis-frame-table\">\n  <thead>\n    <tr>\n      <th>Configuration du capteur<\/th>\n      <th>Nombre maximal de trames<br\/>(pr\u00e9c\u00e9demment)<\/th>\n      <th>Nombre maximal de trames<br\/>(micrologiciel 1.12.0)<\/th>\n    <\/tr>\n  <\/thead>\n  <tbody>\n    <tr>\n      <td>heliSens S4H Single Memory<\/td>\n      <td>1348<\/td>\n      <td>2700<\/td>\n    <\/tr>\n    <tr>\n      <td>heliSens S4H Dual Memory<\/td>\n      <td>1348<\/td>\n      <td class=\"highlight\">4048<\/td>\n    <\/tr>\n    <tr>\n      <td>heliSens S4M Single Memory<\/td>\n      <td>338<\/td>\n      <td>674<\/td>\n    <\/tr>\n    <tr>\n      <td>heliSens S4M Dual Memory<\/td>\n      <td>338<\/td>\n      <td>1022<\/td>\n    <\/tr>\n  <\/tbody>\n<\/table>\n\n<figcaption class=\"wp-element-caption\">\nComparaison du nombre maximal de trames de mesure sur la cam\u00e9ra avant et apr\u00e8s le micrologiciel 1.12. Gr\u00e2ce \u00e0 une gestion optimis\u00e9e de la m\u00e9moire, le nombre de trames de mesure \u2014 et donc la plage de mesure verticale maximale \u2014 a \u00e9t\u00e9 augment\u00e9 jusqu\u2019\u00e0 un facteur trois, selon la configuration du capteur. \n<\/figcaption>\n\n<\/figure>\n\n<div style=\"height:51px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Mise en service et diagnostic bas\u00e9s sur un navigateur<\/h3>\n\n<p class=\"wp-block-paragraph\">Avec le micrologiciel 1.12, une interface utilisateur bas\u00e9e sur un navigateur est disponible pour la premi\u00e8re fois avec heliViewer 4. L\u2019acc\u00e8s se fait directement via un navigateur Web \u2013 aucune installation de logiciel suppl\u00e9mentaire sur le PC h\u00f4te n\u2019est n\u00e9cessaire. <\/p>\n\n<p class=\"wp-block-paragraph\">heliViewer 4 permet la visualisation de topographies, d\u2019images d\u2019amplitude et de donn\u00e9es en direct, ainsi que l\u2019acc\u00e8s direct \u00e0 l\u2019ensemble des param\u00e8tres de la cam\u00e9ra. L\u2019\u00e9ventail des fonctions est compl\u00e9t\u00e9 par des fonctions de diagnostic int\u00e9gr\u00e9es et un assistant de configuration qui guide l\u2019utilisateur \u00e9tape par \u00e9tape lors de la premi\u00e8re mise en service. <\/p>\n\n<p class=\"wp-block-paragraph\">L\u2019acc\u00e8s via navigateur compl\u00e8te les interfaces GenICam, SDK et API existantes. Ainsi, pratiquement n\u2019importe quel PC ou ordinateur portable peut \u00eatre utilis\u00e9 comme station de service ou d\u2019ing\u00e9nierie, ce qui facilite notamment la mise en service, la maintenance et le diagnostic directement sur la machine. <\/p>\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/heliotis.com\/wp-content\/uploads\/2026\/07\/heliViewer4-embedded-Quickstart.pdf\" data-type=\"link\" data-id=\"https:\/\/heliotis.com\/wp-content\/uploads\/2026\/07\/heliViewer4-embedded-Quickstart.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">heliViewer4 embedded &#8211; D\u00e9marrage rapide<\/a><\/p>\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"523\" src=\"https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/heliViewer4a-1024x523.webp\" alt=\"\" class=\"wp-image-28723\" srcset=\"https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/heliViewer4a-1024x523.webp 1024w, https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/heliViewer4a-300x153.webp 300w, https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/heliViewer4a-768x392.webp 768w, https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/heliViewer4a.webp 1267w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Le logiciel heliViewer 4 bas\u00e9 sur un navigateur simplifie la mise en service, l\u2019entretien et le diagnostic, et compl\u00e8te les interfaces GenICam et SDK de la plateforme Gen4.<\/figcaption><\/figure>\n\n<div style=\"height:51px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Int\u00e9gration transparente dans les syst\u00e8mes de vision industrielle &#8211; d\u00e9sormais aussi pour Cognex VisionPro<\/h3>\n\n<p class=\"wp-block-paragraph\">L\u2019int\u00e9gration dans les environnements de vision industrielle existants est un objectif de d\u00e9veloppement central de la plateforme Heliotis Gen4 depuis de nombreuses ann\u00e9es. Toutes les fonctions de la cam\u00e9ra sont disponibles via <strong>GenICam<\/strong> conform\u00e9ment aux normes et peuvent ainsi \u00eatre int\u00e9gr\u00e9es dans la plupart des biblioth\u00e8ques de vision industrielle sans effort de d\u00e9veloppement suppl\u00e9mentaire. <\/p>\n\n<p class=\"wp-block-paragraph\"><strong>En tant que membre votant du consortium GenICam<\/strong>, Heliotis participe activement au d\u00e9veloppement de ce standard industriel. En collaboration avec diff\u00e9rents \u00e9diteurs de logiciels, de nombreuses impl\u00e9mentations GenICam ont \u00e9t\u00e9 perfectionn\u00e9es et compl\u00e9t\u00e9es conform\u00e9ment aux normes au cours des derni\u00e8res ann\u00e9es. Aujourd\u2019hui, pratiquement toutes les plateformes de vision industrielle courantes compatibles GenICam supportent l\u2019int\u00e9gration des syst\u00e8mes heliInspect.  <\/p>\n\n<p class=\"wp-block-paragraph\">Avec le micrologiciel 1.12, cet \u00e9cosyst\u00e8me logiciel s\u2019enrichit du support de Cognex VisionPro. Comme l\u2019interface GenICam de VisionPro ne supporte pas encore int\u00e9gralement les fonctions requises pour heliInspect, l\u2019int\u00e9gration a \u00e9t\u00e9 r\u00e9alis\u00e9e via l\u2019\u00ab Application Integration Kit \u00bb de Cognex. Ainsi, heliInspect est d\u00e9sormais disponible nativement pour les utilisateurs de Cognex VisionPro, sans middleware suppl\u00e9mentaire.  <\/p>\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"379\" src=\"https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/supported_vision_libraries3-e1783348840653-1024x379.webp\" alt=\"\" class=\"wp-image-28721\" srcset=\"https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/supported_vision_libraries3-e1783348840653-1024x379.webp 1024w, https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/supported_vision_libraries3-e1783348840653-300x111.webp 300w, https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/supported_vision_libraries3-e1783348840653-768x284.webp 768w, https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/supported_vision_libraries3-e1783348840653-1536x568.webp 1536w, https:\/\/www.heliotis.com\/wp-content\/uploads\/2026\/07\/supported_vision_libraries3-e1783348840653.webp 1774w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Environnements de d\u00e9veloppement et de vision industrielle support\u00e9s par la plateforme Heliotis Gen4. Le SDK 1.12 \u00e9tend le support natif de Cognex VisionPro \u00e0 cet \u00e9cosyst\u00e8me logiciel. <\/figcaption><\/figure>\n\n<div style=\"height:51px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Nouvelles fonctions pour les cam\u00e9ras Lock-in heliCam<\/h3>\n\n<p class=\"wp-block-paragraph\">Les interf\u00e9rom\u00e8tres \u00e0 lumi\u00e8re blanche heliInspect ne sont pas les seuls \u00e0 b\u00e9n\u00e9ficier des versions 1.11 et 1.12 du micrologiciel. Les heliCam C4 et C4M ont \u00e9galement \u00e9t\u00e9 enrichies de nouvelles fonctions qui acc\u00e9l\u00e8rent les processus de mesure, simplifient la synchronisation d\u2019exp\u00e9riences complexes et facilitent la mise en service. <\/p>\n\n<h4 class=\"wp-block-heading\">Accumulation I\/Q sur la cam\u00e9ra<\/h4>\n\n<p class=\"wp-block-paragraph\">De nombreuses applications Lock-in reposent sur la moyenne d\u2019un grand nombre de mesures I\/Q. Avec le micrologiciel 1.11, cette accumulation peut d\u00e9sormais s\u2019effectuer directement sur la cam\u00e9ra. Au lieu de transmettre toutes les trames I\/Q individuelles au PC h\u00f4te, seules une image I accumul\u00e9e et une image Q accumul\u00e9e sont transmises.  <\/p>\n\n<p class=\"wp-block-paragraph\">Selon l\u2019application, le volume de donn\u00e9es \u00e0 transmettre est ainsi consid\u00e9rablement r\u00e9duit, ce qui peut raccourcir nettement le temps de mesure global. Parall\u00e8lement, un nombre bien plus important de mesures individuelles peut \u00eatre regroup\u00e9 en une seule acquisition. <\/p>\n\n<h4 class=\"wp-block-heading\">Nouvelles options de d\u00e9clenchement pour les montages de mesure complexes<\/h4>\n\n<p class=\"wp-block-paragraph\">Un nouveau mode de d\u00e9clenchement (trigger) permet de d\u00e9marrer chaque trame de mesure I\/Q individuelle d\u2019une s\u00e9quence par un signal de d\u00e9clenchement externe. Cela permet de synchroniser beaucoup plus facilement l\u2019heliCam avec des exp\u00e9riences externes. <\/p>\n\n<p class=\"wp-block-paragraph\">Un exemple typique est la synchronisation avec un signal carr\u00e9 \u00e0 haute fr\u00e9quence. En combinaison avec le \u00ab Quarter-Period-Triggering \u00bb, la relation de phase entre les diff\u00e9rentes mesures reste exactement d\u00e9finie et reproductible. <\/p>\n\n<h4 class=\"wp-block-heading\">Mode d\u2019intensit\u00e9 de bas niveau (Low-Level-Intensity)<\/h4>\n\n<p class=\"wp-block-paragraph\">Avec le micrologiciel 1.12, un mode d\u2019intensit\u00e9 de bas niveau est \u00e9galement disponible. Celui-ci fournit une image d\u2019intensit\u00e9 en direct semblable \u00e0 celle d\u2019une cam\u00e9ra conventionnelle et facilite notamment la mise en service des montages optiques. <\/p>\n\n<p class=\"wp-block-paragraph\">Ce mode convient par exemple pour la mise au point, l\u2019alignement de composants optiques ou le positionnement d\u2019un \u00e9chantillon. En compl\u00e9ment, des programmes d\u2019exemple pour Python et MATLAB sont disponibles pour faciliter l\u2019initiation \u00e0 la commande de la cam\u00e9ra et l\u2019int\u00e9gration dans son propre logiciel de mesure. <\/p>\n\n<div style=\"height:51px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n<h3 class=\"wp-block-heading\">Conclusion<\/h3>\n\n<p class=\"wp-block-paragraph\">Les versions 1.11 et 1.12 du micrologiciel enrichissent la plateforme Heliotis Gen4 de nombreuses nouvelles fonctions et am\u00e9liorations de performance. Qu\u2019il s\u2019agisse d\u2019une pr\u00e9cision de mesure accrue, d\u2019une plage de mesure verticale plus \u00e9tendue, d\u2019une mise en service via navigateur, d\u2019une int\u00e9gration logicielle transparente ou de nouvelles fonctions pour l\u2019heliCam, les syst\u00e8mes existants en b\u00e9n\u00e9ficient \u2013 sans aucune modification du mat\u00e9riel. <\/p>\n\n<p class=\"wp-block-paragraph\">Chez Heliotis, le d\u00e9veloppement des produits ne s\u2019arr\u00eate pas \u00e0 la livraison d\u2019un syst\u00e8me. Les nouvelles versions du micrologiciel enrichissent continuellement la plateforme de fonctions suppl\u00e9mentaires et d\u2019am\u00e9liorations de performance, garantissant que les installations existantes profitent \u00e9galement du progr\u00e8s technologique \u00e0 long terme. <\/p>\n\n<p class=\"wp-block-paragraph\">Pour nos clients, cela signifie une protection \u00e9lev\u00e9e de leur investissement : une part essentielle de l\u2019innovation provient aujourd\u2019hui des mises \u00e0 jour du micrologiciel et du logiciel, et non du remplacement du mat\u00e9riel. Ainsi, le cycle de vie technologique de la plateforme Gen4 est prolong\u00e9 et les syst\u00e8mes existants gagnent continuellement en performance. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Avec les versions 1.11 et 1.12 du micrologiciel, Heliotis continue de d\u00e9velopper de mani\u00e8re coh\u00e9rente la plateforme Gen4 pour heliInspect et heliCam. Outre de nombreuses am\u00e9liorations de d\u00e9tail, les utilisateurs b\u00e9n\u00e9ficient notamment d\u2019une pr\u00e9cision de mesure accrue des interf\u00e9rom\u00e8tres \u00e0 lumi\u00e8re blanche heliInspect, d\u2019une plage de mesure verticale plus \u00e9tendue, de nouvelles possibilit\u00e9s d\u2019int\u00e9gration ainsi [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":27136,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[39],"tags":[],"class_list":["post-28791","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-produits"],"_links":{"self":[{"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/posts\/28791","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/comments?post=28791"}],"version-history":[{"count":3,"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/posts\/28791\/revisions"}],"predecessor-version":[{"id":28811,"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/posts\/28791\/revisions\/28811"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/media\/27136"}],"wp:attachment":[{"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/media?parent=28791"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/categories?post=28791"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.heliotis.com\/fr\/wp-json\/wp\/v2\/tags?post=28791"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}