Lock-in demodulation up to 200 kHz, individual frame triggering, on-camera I/Q accumulation, and a quantitative signal and noise model: With the latest firmware release 1.12.1 and the comprehensively expanded user manual, we are further extending the capabilities of our Lock-in cameras.
Heliotis’ Lock-in image sensors enable simultaneous dual-phase demodulation of optical signals across hundreds of thousands to more than one million pixels. The analog signal processing integrated directly into the pixels makes it possible to detect the smallest periodic signal components even against a strong optical background.
Over the past months, we have continuously expanded the functionality of our heliCam™ C4 and C4M through multiple firmware and software releases. The current release 1.12.1 adds further features that are of particular interest for demanding scientific applications.
In parallel, we have comprehensively revised the user manual. It describes the expanded camera functions, provides a deeper understanding of the underlying physical principles, and supports users in implementing their measurement tasks with numerous new programming examples.
New in firmware 1.12.1: Lock-in demodulation up to 200 kHz
With the new High-Speed Mode of the heliCam C4, the maximum demodulation frequency is increased from 121 kHz in standard operation to 200 kHz.
In addition to extending the usable frequency range, higher demodulation frequencies can be advantageous, especially at small modulation depths: The shorter integration intervals of the photodiodes allow higher optical irradiance to be used before pixel saturation occurs. The higher tolerable light intensity can, in turn, lead to an improved signal-to-noise ratio.
High-Speed Mode is enabled by adjusting the sensor-internal timing parameters. The new user manual describes the required settings, the technical boundary conditions, and methods for correcting timing-dependent image artifacts that can occur at high demodulation frequencies.
New in firmware 1.12.1: Individual triggering of Lock-in frames
Precise synchronization of a Lock-in camera with external signal sources, light modulators, and other measurement instruments is a key requirement for many scientific applications.
With the new trigger LockInFrameStart, individual Lock-in frames within a measurement sequence can be triggered individually via the fast digital inputs FI2 and FI3.
This makes it possible to address two use cases in particular:
- Synchronization with external events: Individual Lock-in frames can be captured selectively under changing experimental conditions.
- Reproducible phase relationships: In combination with quarter-period triggering, a defined phase reference can be established between the optical modulation signal and the start of each individual Lock-in measurement.
In addition, the current release improves the stability of image acquisition when using external reference signals, and aligns the reference signal output by the camera in time with the start of exposure of the image sensor.
New in release 1.12.1: ARM64 support
With our GenTL Producer Diaphus, we now also support the ARM64 architecture (aarch64).
This expands the options for integrating our Lock-in cameras into compact, energy-efficient ARM-based computer systems and embedded computing platforms.
This is of particular interest for developing autonomous measurement systems, compact scientific instruments, and customer-specific OEM solutions.
On-camera I/Q accumulation
Many Lock-in applications require long effective integration times to reliably detect very small periodic signal components.
With On-Camera Frame Summation, the demodulated in-phase and quadrature signals (I/Q) of many consecutive measurement frames can be accumulated directly in the camera. Instead of a complete image sequence, only an accumulated I/Q image pair is transferred to the host computer.
This offers several advantages:
- Extending the effective integration time beyond the integration duration of a single Lock-in frame
- Improving the signal-to-noise ratio
- Increasing frequency selectivity with a suitable temporal sequence of measurement frames
- Significantly reducing the amount of data to be transferred
- Lower memory and processing requirements on the host computer
This feature is of particular interest when detecting very small modulation depths, for example in NV-diamond-based magnetometry or fluorescence imaging.
Fixed pattern noise (FPN) correction can also be performed as part of the on-camera accumulation.
The new user manual describes the optimal combination of integration time and frame summation and explains under which conditions on-camera accumulation is particularly advantageous.
Intensity imaging for setting up optical systems
With Low-Level Intensity Mode, the heliCam C4 and C4M can also be used for conventional intensity imaging.
This makes it easier to set up experimental arrangements, for example when focusing the imaging optics, aligning optical components, positioning samples, or checking illumination.
A special feature of this mode is the ability to capture two intensity images per frame with independently configurable exposure times. For this purpose, the I and Q channels of the image sensor, normally used for Lock-in demodulation, are utilized.
Flexible timing control of measurement sequences
The expanded user manual also describes a range of additional functions for timing control, optimization, and analysis of Lock-in measurement sequences.
- Blank Periods: Defined measurement pauses between successive Lock-in frames allow independent adjustment of frame rate and integration time.
- Time Tags: Sensor-generated timestamps enable analysis of the measurement timing and identification of missing trigger events and unexpected timing deviations.
- Frame Synchronization: Outputting synchronization signals enables temporal coordination with other components of the measurement system.
- Pipelined Acquisition: By overlapping measurement and data transfer in time, the frame rate achievable on the host computer can be increased.
These descriptions are complemented by quantitative information on measurement duration, data transfer time, and the maximum achievable frame rates depending on the selected camera parameters.
Signal and noise – a quantitative model of Lock-in pixel technology
What signal-to-noise ratio can be achieved with a Lock-in camera under given conditions? How small can the modulation depth of an optical signal be? What influence do irradiance, demodulation frequency, and integration time have? And which sensor variant is best suited for a particular application?
A new, detailed chapter of the user manual is dedicated to these questions.
Based on the optical responsivity of the sensor pixels, signal generation, the key noise contributions, and the physical saturation limits are described mathematically.
The quantitative model takes into account, among other things:
- Pixel size, quantum efficiency, and optical fill factor
- Modulation waveform, modulation depth, and phase
- Photon noise (photon shot noise)
- Readout noise
- Active background light suppression (background suppression)
- Integration time and saturation limits
For the first time, the sensor-specific characteristic parameters of the various heliSens™ image sensors relevant to the model are documented in this level of detail.
This makes it possible to quantitatively estimate the expected signal-to-noise ratio already when designing an experimental setup. At the same time, the model supports targeted optimization of the optical and electronic measurement parameters of existing systems.
Weak modulation against a strong optical background
A particular strength of heliSens Lock-in pixel technology lies in detecting small periodic signal components while maintaining high optical background intensity.
Active background light suppression takes place already at pixel level, before the actual demodulation. This allows the maximum tolerable optical irradiance—limited by the charge capacity of the photodiodes—to be increased by a factor of about 30 compared to operation without background light suppression.
The new signal and noise model describes both the benefits and the associated additional noise contributions. It shows under which conditions increasing optical power leads to an improved signal-to-noise ratio and which saturation mechanisms limit the usable operating range.
Interpreting measurement data near the detection limit
The new manual also covers the statistical properties of the demodulated amplitude and phase signals.
For example, at low signal-to-noise ratio, the amplitude calculated from the two Lock-in components I and Q exhibits a systematic positive bias. Understanding such statistical effects is particularly important for quantitative evaluation of very weak modulation signals.
Expert Workflows – from camera function to practical application
A completely new chapter of the user manual is dedicated to advanced measurement methods and the optimal configuration of the heliCam C4 and C4M.
Nine Expert Workflows address typical real-world tasks:
- Reference Synchronization: Precise synchronization with external reference signals
- Lock-in Frame Triggering: Individual triggering of single Lock-in frames
- Intensity Mode: Conventional intensity imaging
- On-Camera Frame Summation: On-camera accumulation of the I/Q signals
- High-Speed Mode: Demodulation frequencies up to 200 kHz
- Row-Noise Correction: Correction of time-varying row-dependent image artifacts
- Maximizing Refresh Rate: Optimizing the achievable refresh rate
- Time Tags: Analysis of measurement timing
- Blank Periods: Independent adjustment of integration time and frame rate
Alongside the description of the expanded camera functions, the focus is also on methods for improving measurement quality and accelerating measurement workflows.
For example, it describes how the light-insensitive reference pixels in the outermost sensor columns can be used to correct time-varying row-dependent image artifacts.
The Expert Workflows are complemented by numerous new Python programming examples. These are part of the current C4Utility and can be used as a starting point for implementing your own measurement and analysis applications.
Updated specifications of the megapixel Lock-in camera
The new manual also includes the technical specifications of the current generation of our megapixel Lock-in camera, heliCam C4M.
Compared to the original sensor generation, light sensitivity has been significantly increased:
| Sensor parameters | S4M0 | S4M1U |
|---|---|---|
| Resolution | 1024 × 1102 | 1024 × 1102 |
| Optical fill factor | 23% | 55% |
| Full well capacity | 70,000 e⁻ | 140,000 e⁻ |
| Detection threshold (1 kHz, 10 ms) | 1.2 mW/m² | 0.5 mW/m² |
| Detection threshold (10 kHz, 1 ms) | 12 mW/m² | 5 mW/m² |
With the S4M1U sensor, the minimum detectable irradiance has been reduced by a factor of 2.4 compared to the previous generation, while doubling the charge capacity of the photodiodes.
Continuous development of our Lock-in platform
At Heliotis, product development does not end with the delivery of a camera. Through continuous firmware and software updates, we expand the functionality of our Gen4 platform and open up new possibilities for existing users as well.
Whether quantum sensing, fluorescence imaging, optical metrology, or the development of entirely new imaging measurement methods – the expanded camera functions and the new user manual support scientists and engineers from the initial feasibility assessment and optimization of the measurement setup through to integration into complex measurement systems.
For particularly demanding applications, we also offer a calculation tool and technical support to estimate the expected signal-to-noise ratio and saturation limits.
Firmware release 1.12.1, the updated C4Utility, and the new heliCam C4 user manual are now available in our download area.